Description
The 200 A / 2000 A current clamp allows you to measure up to 2000 amps without cutting, or disconnecting or stripping wires. Simply clamp the jaws around the cable to be tested and plug the clamp into your PicoScope.
The TA167 features a 200 A mode for better performance at lower currents and has an increased jaw size. It also features an auto power-down facility to save battery life when not in use (this feature can be disabled for battery drain / shutdown current testing).
Specifications
Electrical data |
(All accuracies stated at 23°C ± 1°C)
|
Nominal current |
2000 A AC pk max. or DC
|
Measuring range(s) |
2000 A |
Overload capacity |
2200 A (60 s) |
Output sensitivity |
10 mV/A and 1 mV/A switchable |
Accuracy1) (0 to 200 A of 10 mV/A) |
± 1% of reading ± 100 mA |
Accuracy1) (0 to 1500 A of 1 mV/A) |
± 1% of reading ± 500 mA |
Accuracy1) (1500 to 2000 A of 1 mV/A) |
± 5% of reading |
Gain variation |
±0.15% of reading/°C |
Frequency range |
DC to 20 kHz (–1 dB) |
|
iRMS x f ≤ 400,000 |
Power supply |
9 V alkaline battery
PP3, MN 1604
or IEC6LR61 |
Load impedance (minimum) |
> 100 kΩ and ≤ 100 pF |
General data |
Conductor size |
32 mm diameter |
Output cable and connectors |
2 m long coax terminated with safety BNC connector |
Operating temperature |
0°C to +50°C |
Storage temperature with Battery removed |
–20°C to +85°C |
|
|
1)Accuracy quoted is for conductor in centre of aperture